Recently, many urban areas around the world, especially in hot climates suffered from the
mounting negative consequences of climate change and the Urban Heat Island (UHI)
phenomenon which deteriorated the outdoor and indoor thermal conditions and increased
energy demand. To face the negative consequences resulting from the climate change
phenomenon, there is an increasing interest in improving indoor and outdoor thermal
conditions and reaching energy-efficient buildings, especially for the constructed urban areas
in hot arid climates. To achieve this target, this study focuses on three main strategies: passive
sustainable design (natural ventilation), energy-saving techniques (Green roof) and generating
on-site energy through renewable resources (PV system). للخاليا الشمسية من خالل رش رذاذ الماء فوق السطح العلوي لها، أو من خالل زيادة سرعة الهواء أسفل الخاليا الشمسية
إلى زيادة كفاءة الخاليا الشمسية الكهربائية بنسبة تصل إلى ،%3.93 و،%4.75 و%6.21 على التوالي. أدى الجمع بين
جميع التقنيات الثالثة السابقة مع االسطح الخضراء إلى زيادة اإلنتاج الكهربائي وتحسين االداء الحراري للخاليا الشمسية
بنسبة ٪10.73 و٪51.13 على التوالي. وبالنسبة لألثر االقتصادي والبيئي لنظام المتكامل بين الخاليا الشمسية واالسطح
الخضراء، فانه يمكن لهذا النظام أن يقلل من انبعاثات ثاني أكسيد الكربون سنويًا بمقدار 59.56 كجم و1.191 طن لمدة 20
عا ًما من عمر النظام. كما سيوفر هذا النظام 9.7 دوال ًرا أمريكيًا/ سنويًا )194.16 دوال ًرا أمريكيًا/ 20 عا ًما( كان يمكن
انفاقها للتخلص من هذه االنبعاثات.
Integrated renewable and greening system solutions towards energy efficient buildings / التكامل بين أنظمة الطاقة المتجددة و الخضراء للوصول الي مباني ذات كفاءة طاقة. Mohamed Emad Abdalazeem Kamel. - Alexandria : Mohamed Emad Abdalazeem Kamel, 2024. - 119 Leaves ; 30 cm
A Thesis Submitted to the School of Energy Resources, Environmental, Chemical and Petrochemical Engineering, Egypt-Japan University of Science and Technology (E-JUST) : In Partial Fulfillment of the Requirements for the Degree of Doctor of Philosophy in Environmental Engineering.
Thesis (Ph.D.
Includes bibliographical references.
Recently, many urban areas around the world, especially in hot climates suffered from the
mounting negative consequences of climate change and the Urban Heat Island (UHI)
phenomenon which deteriorated the outdoor and indoor thermal conditions and increased
energy demand. To face the negative consequences resulting from the climate change
phenomenon, there is an increasing interest in improving indoor and outdoor thermal
conditions and reaching energy-efficient buildings, especially for the constructed urban areas
in hot arid climates. To achieve this target, this study focuses on three main strategies: passive
sustainable design (natural ventilation), energy-saving techniques (Green roof) and generating
on-site energy through renewable resources (PV system). للخاليا الشمسية من خالل رش رذاذ الماء فوق السطح العلوي لها، أو من خالل زيادة سرعة الهواء أسفل الخاليا الشمسية
إلى زيادة كفاءة الخاليا الشمسية الكهربائية بنسبة تصل إلى ،%3.93 و،%4.75 و%6.21 على التوالي. أدى الجمع بين
جميع التقنيات الثالثة السابقة مع االسطح الخضراء إلى زيادة اإلنتاج الكهربائي وتحسين االداء الحراري للخاليا الشمسية
بنسبة ٪10.73 و٪51.13 على التوالي. وبالنسبة لألثر االقتصادي والبيئي لنظام المتكامل بين الخاليا الشمسية واالسطح
الخضراء، فانه يمكن لهذا النظام أن يقلل من انبعاثات ثاني أكسيد الكربون سنويًا بمقدار 59.56 كجم و1.191 طن لمدة 20
عا ًما من عمر النظام. كما سيوفر هذا النظام 9.7 دوال ًرا أمريكيًا/ سنويًا )194.16 دوال ًرا أمريكيًا/ 20 عا ًما( كان يمكن
انفاقها للتخلص من هذه االنبعاثات.