Welcome To E-JUST Library

Local cover image
Local cover image

Mechatronic Design of a Microfluidic System for in-Liquid Biosensing : A Thesis Submitted to the Graduate School of Innovative Design Engineering : Egypt-Japan University of Science and Technology (E-JUST) : In Partial Fulfillment of the Requirements for the Degree of Doctor of Philosophy in Mechatronics and Robotics Engineering / by Mohamed Adel Mohamed Abdallah ; Supervisor Committee Prof. Ahmed Fath El-Bab - Department of Mechatronics and Robotics Engineering - E-JUST - Egypt , Dr. Ahmed Allam - Department of Electronics and Communications Engineering - E-JUST - Egypt , Prof. Shinjiro Umezu - Department of Modem Mechanical Engineering - Waseda University - Japan , Prof. Hani Fikry - Electronics and Communications Department - Ain Shams University - Egypt , Prof. Hossam Sayour - Animal Health Research Institute - Agricultural Research Center - Egypt ; Examination Committee Prof. Said Megahed - Mechanical Design and Production Department - Cairo University - Egypt , Prof. Hassan Warda - Mechanical Engineering Department - Alexandria University - Egypt , Prof. Ahmed Fath El-Bab - Department of Mechatronics Robotics Engineering - E-Just - Egypt

By: Contributor(s): Material type: TextTextLanguage: English Summary language: Arabic Publication details: Alexandria : Mohamed Adel Mohamed Abdallah 2024Description: 91 leaves ; 30 cmOther title:
  • تصميم ميكاترونى لنظام موائع دقيق للاستشعار الحيوي داخل السوائل : رسالة علمية مقدمة إلى المدرسة التخصصية للدرسات العليا - مدرسة هندسة التصميم الإبداعي : الجامعة المصرية اليابانية للعلوم و التكنولوجيا كاستيفاء جزئي لمتطلبات الحصول على درجة دكتوراة الفلسفة في هندسة الميكاترونيات و الروبوتات / إعداد محمد عادل محمد عبدالله ; لجنة الإشراف على الرسالة أ . د . أحمد فتح الباب , د. أحمد علام , أ . د . شينجيرو أوميزو , أ . د . هانی فکری , أ . د . حسام سپور ; لجنة المناقشة و الحكم على الرسالة أ . د . سعيد مجاهد , أ . د . حسن وردة , أ . د . أحمد فتح الباب [Added title page title]
LOC classification:
  • AIS Phd. 2024 01 C.1
Issued also as a digital file (for more information please check our Digital Repository)Dissertation note: Thesis (Ph.D.) Doctoral Egypt - Japan University of Science and Technology (E-JUST) - School of Innovative Design Engineering - Mechatronics and Robotics Engineering Department 2024 Summary: Quartz crystal microbalance (QCM) is a powerful sensing technique widely used in various applications, including biosensing, chemical analysis, and material science. This thesis presents a portable QCM system for liquid biosensing that uses a modified Hartley oscillator to drive 14 mm-diameter commercial QCM sensors. The system is designed to be low-cost, easy to use, and highly sensitive A new flow cell design to deliver samples to the surface of the sensor has been designed, fabricated, and tested For portability and miniaturization purposes, a micropump-based pumping system is used The system has a built-in temperature controller, allowing for accurate frequency measurements. In addition, the system can be used in benchtop mode The capability of the system to be used in liquid biosensing is demonstrated through experimental tests for sensitivity to changes in the viscosity of glycerol samples It was found to have a sensitivity of 263.51 Hz/mPas using a 10 MHz QCM sensor QCM measurements are susceptible to fluctuations in fluid flow rate, which can introduce unwanted noise, especially in portable mode Therefore, we present an approach to enhance the stability of measurements by utilizing a microfluidic flow stabilizer We employ a comprehensive methodology that combines computational fluid dynamics (CFD) simulations, microfabrication, and experimental testing to evaluate the effectiveness of the stabilizer in mitigating flow-induced fluctuations Two different designs have been presented and tested The experimental results demonstrated that the first and second designs effectively reduced the fluctuation amplitude in QCM measurements from 100% (input) to 23% and 19% (output)respectivelySummary: بعد التوازن الدقيق لبلورات الكوارتز (QCM) من تقنيات الاستشعار القوية المستخدمة على نطاق واسع في العديد من التطبيقات، بما في ذلك الاستشعار الحيوي والتحليل الكيميائي وعلوم المواد، تعرض الرسالة الحالية نظام QCM محمول للاستشعار الحيوي داخل السوائل و الذي يستخدم مذبذب هارتلي المعدل لتشغيل مستشعرات QCM التجارية المتاحة بقطر 14 مم، تمثلت الأهداف الأساسية أثناء تصميم النظام أن يكون منخفض التكلفة وسهل الاستخدام وحساس للغاية لأى تغيرات على سطح المستشعر، كما تم عرض تصميم جديد لخلية التدفق المستخدمة لتوصيل العينات إلى سطح المستشعر و تصنيعها و اختبارها، ولأغراض التنقل والتصغير، تم استخدام نظام ضخ يعتمد على مضخة دقيقة صغيرة الحجم، يحتوي النظام على متحكم مدمج لضبط درجة الحرارة، مما يسمح بإجراء قياسات دقيقة نظراً لحساسية المستشعر الكبيرة للتغير فى درجة الحرارة المحيطة، بالإضافة إلى الوضع المحمول الذي يُمكن استخدام الجهاز للقياسات الخارجية في المواقع، فقد تم تصميم الجهاز لاستخدامه في وضع الطاولة أيضاً، تم إثبات قدرة النظام على استخدامه في الاستشعار الحيوي داخل السوائل من خلال اختبار الحساسية التجريبي للتغيرات في لزوجة عينات من الجلسرين، أوضحت النتائج أن حساسية الجهاز تبلغ 263.51 هرتز/ مللي باسكال ثانية باستخدام مستشعر QCM بتردد 10 ميجاهرتز تتعرض مستشعرات QCM لتقلبات عديدة في معدل تدفق السوائل على سطح المستشعر بناءً على نوع المضخة، والتي تؤدي إلى ضوضاء غير مرغوب فيها أثناء عملية القياس، خاصة عند استخدام الجهاز في الوضع المحمول، ولذلك، تم عرض نهجأ لتعزيز استقرار القياسات عن طريق استخدام شريحة مواقع دقيقة لتثبت معدل تدفق السوائل، و تم استخدام منهجية شاملة تجمع بين محاكاة ديناميكيات الموائع الحسابية (CFD) والتصنيع الدقيق والاختبار التجريبي لتقييم فعالية الشريحة في تخفيف التقلبات الناجمة عن تدفق السوائل، و تم عرض تصميمين مختلفين و اختبارهما، وأظهرت النتائج التجريبية أن التصميمين الأول والثاني خفضا بشكل فعال سعة التذبذب في قياسات مستشعر QCM من 100% (عند المدخل) إلى 23% و 19% (عند المخرج)، على التوالي
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Barcode
Dissertations Dissertations Fayza Aboulnaga Central Library | مكتبة فايزة أبو النجا المركزية بالحرم الجامعي MTR PhD. 2024 02 C.1 (Browse shelf(Opens below)) C. 1 Not for loan 10014395
Browsing Fayza Aboulnaga Central Library | مكتبة فايزة أبو النجا المركزية بالحرم الجامعي shelves Close shelf browser (Hides shelf browser)
MTR PhD. 2022 02 Design and Implementation of A new Interconnected Translational Manipulator : A Thesis Submitted to the Graduate School of Innovative Design Engineering : Egypt - Japan University of Science and Technology (E - JUST) : In Partial Fulfillment of the Requirements for the Degree of Doctor of Philosophy in Mechatronics and Robotics Engineering / MTR PhD. 2022 03 Design and Control of a Photo Voltaic System for Solar - Powered Exploration Robots : A Thesis Submitted to the Graduate School of Innovative Design Engineering : Egypt - Japan University of Science and Technology (E - JUST) : In Partial Fulfillment of the Requirements for the Degree of Doctor of Philosophy in Mechatronics and Robotics Engineering / MTR PhD. 2024 01 Optimization Of Electromagnetic Launcher Carried On A Robot For Space Applications : A Thesis Submitted To The Graduate School Of Innovative Design Engineering , Egypt - Japan University Of Science And Technology (E-JUST) In Partial Fulfillment Of The Requirements For The Degree Of Doctor Of Philosopy In Mechatronics And Robotics Engineering / MTR PhD. 2024 02 C.1 Mechatronic Design of a Microfluidic System for in-Liquid Biosensing : A Thesis Submitted to the Graduate School of Innovative Design Engineering : Egypt-Japan University of Science and Technology (E-JUST) : In Partial Fulfillment of the Requirements for the Degree of Doctor of Philosophy in Mechatronics and Robotics Engineering / N40 .K6713 2016 50 Artists You Should Know / N66 .D49 2011 الفن خبرة / N66 .D49 2011 الفن خبرة /

Includes a title page in Arabic

Thesis (Ph.D.)
Doctoral Egypt - Japan University of Science and Technology (E-JUST) - School of Innovative Design Engineering - Mechatronics and Robotics Engineering Department 2024

Includes bibliographical references

Quartz crystal microbalance (QCM) is a powerful sensing technique widely used in various applications, including biosensing, chemical analysis, and material science. This thesis presents a portable QCM system for liquid biosensing that uses a modified Hartley oscillator to drive 14 mm-diameter commercial QCM sensors. The system is designed to be low-cost, easy to use, and highly sensitive A new flow cell design to deliver samples to the surface of the sensor has been designed, fabricated, and tested For portability and miniaturization purposes, a micropump-based pumping system is used The system has a built-in temperature controller, allowing for accurate frequency measurements. In addition, the system can be used in benchtop mode The capability of the system to be used in liquid biosensing is demonstrated through experimental tests for sensitivity to changes in the viscosity of glycerol samples It was found to have a sensitivity of 263.51 Hz/mPas using a 10 MHz QCM sensor QCM measurements are susceptible to fluctuations in fluid flow rate, which can introduce unwanted noise, especially in portable mode Therefore, we present an approach to enhance the stability of measurements by utilizing a microfluidic flow stabilizer We employ a comprehensive methodology that combines computational fluid dynamics (CFD) simulations, microfabrication, and experimental testing to evaluate the effectiveness of the stabilizer in mitigating flow-induced fluctuations Two different designs have been presented and tested The experimental results demonstrated that the first and second designs effectively reduced the fluctuation amplitude in QCM measurements from 100% (input) to 23% and 19% (output)respectively

بعد التوازن الدقيق لبلورات الكوارتز (QCM) من تقنيات الاستشعار القوية المستخدمة على نطاق واسع في العديد من التطبيقات، بما في ذلك الاستشعار الحيوي والتحليل الكيميائي وعلوم المواد، تعرض الرسالة الحالية نظام QCM محمول للاستشعار الحيوي داخل السوائل و الذي يستخدم مذبذب هارتلي المعدل لتشغيل مستشعرات QCM التجارية المتاحة بقطر 14 مم، تمثلت الأهداف الأساسية أثناء تصميم النظام أن يكون منخفض التكلفة وسهل الاستخدام وحساس للغاية لأى تغيرات على سطح المستشعر، كما تم عرض تصميم جديد لخلية التدفق المستخدمة لتوصيل العينات إلى سطح المستشعر و تصنيعها و اختبارها، ولأغراض التنقل والتصغير، تم استخدام نظام ضخ يعتمد على مضخة دقيقة صغيرة الحجم، يحتوي النظام على متحكم مدمج لضبط درجة الحرارة، مما يسمح بإجراء قياسات دقيقة نظراً لحساسية المستشعر الكبيرة للتغير فى درجة الحرارة المحيطة، بالإضافة إلى الوضع المحمول الذي يُمكن استخدام الجهاز للقياسات الخارجية في المواقع، فقد تم تصميم الجهاز لاستخدامه في وضع الطاولة أيضاً، تم إثبات قدرة النظام على استخدامه في الاستشعار الحيوي داخل السوائل من خلال اختبار الحساسية التجريبي للتغيرات في لزوجة عينات من الجلسرين، أوضحت النتائج أن حساسية الجهاز تبلغ 263.51 هرتز/ مللي باسكال ثانية باستخدام مستشعر QCM بتردد 10 ميجاهرتز تتعرض مستشعرات QCM لتقلبات عديدة في معدل تدفق السوائل على سطح المستشعر بناءً على نوع المضخة، والتي تؤدي إلى ضوضاء غير مرغوب فيها أثناء عملية القياس، خاصة عند استخدام الجهاز في الوضع المحمول، ولذلك، تم عرض نهجأ لتعزيز استقرار القياسات عن طريق استخدام شريحة مواقع دقيقة لتثبت معدل تدفق السوائل، و تم استخدام منهجية شاملة تجمع بين محاكاة ديناميكيات الموائع الحسابية (CFD) والتصنيع الدقيق والاختبار التجريبي لتقييم فعالية الشريحة في تخفيف التقلبات الناجمة عن تدفق السوائل، و تم عرض تصميمين مختلفين و اختبارهما، وأظهرت النتائج التجريبية أن التصميمين الأول والثاني خفضا بشكل فعال سعة التذبذب في قياسات مستشعر QCM من 100% (عند المدخل) إلى 23% و 19% (عند المخرج)، على التوالي

Issued also as a digital file (for more information please check our Digital Repository)

AnD ACM

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image

All Rights Reserved
Egypt-Japan University of Science and Technology (E-JUST) © 2024