TY - BOOK AU - Hamouda ,Ahmed Amr Zakaria Mohamed AU - Adel B.Abdel-Rahman AU - Asano Tanemasa AU - Ahmed Allam AU - Adel B.Abdel-Rahman AU - Ehab Khalaf Ibrahim Hamad AU - Ahmed Ailam AU - Hany Ahmed Atallah Mohamed AU - بدير ,عادل AU - تناميسا ,اسانو AU - علام ,احمد AU - بدير ,عادل AU - حمد ,ايهاب خلف ابراهيم AU - علام ,احمد AU - محمد ,هاني احمد عطالله TI - High Performance Portable Non Invasive Blood Glucometer : : A Thesis Submitted to the School of Electronics , Communications and Computer Engineering (ECCE) , Faculty of Engineering and Applied Sciences (FEAS) : Egypt - Japan University of Science and Technology (E-JUST) : In Partial Fulfillment of the Requirements for the Degree of Master of Science In Electronics and Communications Engineering / AV - ECE MSc. 2024 01 PY - 2024/// CY - Alexandria : PB - Ahmed Amr Zakaria Mohamed Hamouda N1 - Includes a title page in Arabic; Thesis (M.Sc.); Includes bibliographical references ; Issued also as a digital file (for more information please check our Digital Repository) N2 - This research investigates the design and performance of non - invasive blood glucose sensors using microwave resonators with two different permittiv - ity substrates : Rogers 4360G2 (6.15) and Rogers 4003C (3.38) Numerical simulations were used to analyze the sensors' sensitivity and losses The results demonstrated that the sensor with higher permittivity (e = 6.15) exhibited greater sensitivity (1.1 dB per mg/dL) and lower losses (0.55) compared to the sensor with lower permittivity (e = 3.38), which showed a sensitivity of 0.08 dB per mg/dL and losses of 0.68 These findings suggest that the sensor with higher permittivity (e = 6.15) is more effective for continuous glucose monitoring due to its superior sensitivity and energy efficiency Future work will focus on experimental vali - dation of these findings and further optimization of sensor designs to enhance their performance for non - invasive blood glucose monitoring applications The second study of this research explores the impact of resonator proximity on sensitivity in sensor design , utilizing Rogers 4360G2 as the substrate material with a dielectric constant (e) of 6.15. The study compares the sensitivity of near and far resonators using $21 measurements to evaluate their ability to detect and measure changes in the system The results indicate that near resonators , positioned closer to the energy source or target , exhibit higher sensitivity due to improved energy storage and transmission efficiency In contrast , far resonators positioned at a greater distance demonstrate reduced sensitivity, making it harder to detect subtle variations This research emphasizes the importance of selecting resonator configurations based on specific application requirements Leveraging the advantages of near resonators enables the development of highly sensitive and accurate sensing systems , enhancing performance and expanding capabilities across various fields , including non - invasive blood glucose monitoring; هذا البحث يستكشف تصميم و أداء أجهزة استشعار لقياس مستوى السكر في الدم بدون إجراء اختبارات باستخدام موجات مايكروية مع نوعين مختلفين من المواد العازلة ذات ثابت عزل كهربائي مختلف بين نوعين (6,15 - Rogers 436002 (e و (3,38 - Rogers 4003 (e تم استخدام المحاكاة العددية لتحليل حساسية و فقدان الحساسية في أجهزة الاستشعار هذه أظهرت النتائج أن جهاز الاستشعار ذو ثابت العزل الأعلى (6.15 ) أظهر حساسية أكبر (11) ديسيبل لكل ملليغرام ديسيلتر) و فقدان أقل (0.55) مقارنة بجهاز الاستشعار ذو ثابت العزل الأقل(3.38 = e) ، و الذي أظهر حساسية 0.08 ديسيبل لكل ملليغرام / ديسيلتر و فقدان 0.68 هذه النتائج تشير إلى أن جهاز الاستشعار ذو ثابت العزل الأعلى (6.15 ) أكثر فعالية لمراقبة السكر المستمر بسبب حساسيته العالية و كفاءة الطاقة سيركز العمل المستقبلي على التحقق التجريبي من هذه النتائج و تحسين تصميم أجهزة الاستشعار بشكل أكبر لتعزيز أدائها في تطبيقات مراقبة مستوى السكر في الدم بدون إجراء اختبارات الدراسة الثانية في هذا البحث تستكشف تأثير قرب مركن الترددات على الحساسية في تصميم أجهزة الاستشعار باستخدام 436062 Rogers كمادة أساس ذات ثابت عزل كهربائي (ع) يبلغ 6.15 تقارن الدراسة حساسية المرينات القريبة و البعيدة باستخدام قياسات 521 لتقييم قدرتها على اكتشاف و قياس التغييرات في النظام تشير النتائج إلى أن المرينات القريبة ، و التي تقع على مسافة قريبة من مصدر الطاقة أو الهدف ، تظهر حساسية أعلى بسبب تحسن كفاءة تخزين و إرسال الطاقة في المقابل، تظهر المرينات البعيدة ، و التي تقع على مسافة أكبر ، حساسية منخفضة ، مما يجعل من الصعب اكتشاف التغييرات الطفيفة يؤكد هذا البحث على أهمية اختيار تكوينات المربنات على أساس متطلبات التطبيق المحدد الاستفادة من مزايا المرينات القريبة يمكن من تطوير أنظمة استشعار عالية الحساسية و دقيقة ، و تعزيز الأداء و توسيع القدرات في مجالات متنوعة ، بما في ذلك مراقبة مستوى السكر في الدم بدون إجراء اختبارات ER -