100 | 1 | _aHamouda , Ahmed Amr Zakaria Mohamed , | |
245 | 1 | 0 |
_aHigh Performance Portable Non Invasive Blood Glucometer : _bA Thesis Submitted to the School of Electronics , Communications and Computer Engineering (ECCE) , Faculty of Engineering and Applied Sciences (FEAS) : Egypt - Japan University of Science and Technology (E-JUST) : In Partial Fulfillment of the Requirements for the Degree of Master of Science In Electronics and Communications Engineering / _cby Ahmed Amr Zakaria Mohamed Hamouda ; Supervision Committee Prof. Adel B. Abdel-Rahman - Professor - Electronics and Communications Engineering Department - E-JUST - Egypt , Prof. Asano Tanemasa - Professor -Graduate School of Information Science and Electrical Engineering - Kyushu University - Fukuoka - Japan , Assoc. Prof. Ahmed Allam - Associate Professor - Electronics and Communications Engineering Department - E-JUST - Egypt ; Examination Committee , Prof. Adel B. Abdel-Rahman - Professor - Electronics and Communications Engineering Department - E-JUST - Egypt , Prof. Ehab Khalaf Ibrahim Hamad - Professor - Chairman Electrical Engineering Department - Aswan University - Egypt , Assoc. Prof. Ahmed Ailam - Associate Professor - Electronics and Communications Engineering Department - E-JUST - Egypt , Assoc. Prof. Hany Ahmed Atallah Mohamed - Associate Professor, Electrical Engineering Department - Qena Faculty of Engineering - South Valley University - Egypt |
246 | 1 | 5 |
_aنظام عالي الأداء لقياس الجلوكوز في الدم بدون وخز : _bرسالة علمية مقدمة إلى المدرسة التخصصية للدراسات العليا - هندسة : الجامعة المصرية اليابانية للعلوم و التكنولوجيا كاستيفاء جزئي لمتطلبات الحصول على درجة ماجستير العلوم في هندسة الإلكترونيات و الاتصالات / إعداد احمد عمرو زكريا محمد حموده ; لجنة الاشراف على الرسالة أ . د / عادل بدير - أستاذ بقسم هندسة الإلكترونيات و الاتصالات بالجامعة المصرية اليابانية للعلوم و التكنولوجيا - مصر , أ . د / اسانو تناميسا - أستاذ بكلية الدراسات العليا لعلوم المعلومات و الهندسة الكهربائية بجامعة كيوشو - فوكوكا - اليابان , أ . د . م / احمد علام - أستاذ بقسم هندسة الإلكترونيات و الاتصالات بالجامعة المصرية اليابانية للعلوم و التكنولوجيا - مصر ; لجنة المناقشة و الحكم على الرسالة أ . د / عادل بدير - أستاذ بقسم هندسة الإلكترونيات و الاتصالات بالجامعة المصرية اليابانية للعلوم و التكنولوجيا - مصر , أ . د / ايهاب خلف ابراهيم حمد - استاذ و رئيس قسم الهندسة الكهربية بكلية الهندسة - جامعة اسوان , أ . د . م / احمد علام - أستاذ بقسم هندسة الإلكترونيات و الاتصالات بالجامعة المصرية اليابانية للعلوم و التكنولوجيا - مصر , أ . د . م / هاني احمد عطالله محمد - استاذ مشارك بقسم الهندسة الكهربية - كلية الهندسة بقنا |
260 |
_aAlexandria : _bAhmed Amr Zakaria Mohamed Hamouda _c2024 |
||
300 |
_aleaves 62 ; _c30 cm |
||
500 | _aIncludes a title page in Arabic | ||
502 |
_aThesis (M.Sc.) _bMaster _cEgypt - Japan University of Science and Technology (E - JUST) - School of Electronics , Communications and Computer Engineering (ECCE) , Faculty of Engineering and Applied Sciences (FEAS) - Electronics and Communications Engineering Department _d2024 |
||
504 | _aIncludes bibliographical references | ||
520 | _aThis research investigates the design and performance of non - invasive blood glucose sensors using microwave resonators with two different permittiv - ity substrates : Rogers 4360G2 (6.15) and Rogers 4003C (3.38) Numerical simulations were used to analyze the sensors' sensitivity and losses The results demonstrated that the sensor with higher permittivity (e = 6.15) exhibited greater sensitivity (1.1 dB per mg/dL) and lower losses (0.55) compared to the sensor with lower permittivity (e = 3.38), which showed a sensitivity of 0.08 dB per mg/dL and losses of 0.68 These findings suggest that the sensor with higher permittivity (e = 6.15) is more effective for continuous glucose monitoring due to its superior sensitivity and energy efficiency Future work will focus on experimental vali - dation of these findings and further optimization of sensor designs to enhance their performance for non - invasive blood glucose monitoring applications The second study of this research explores the impact of resonator proximity on sensitivity in sensor design , utilizing Rogers 4360G2 as the substrate material with a dielectric constant (e) of 6.15. The study compares the sensitivity of near and far resonators using $21 measurements to evaluate their ability to detect and measure changes in the system The results indicate that near resonators , positioned closer to the energy source or target , exhibit higher sensitivity due to improved energy storage and transmission efficiency In contrast , far resonators positioned at a greater distance demonstrate reduced sensitivity, making it harder to detect subtle variations This research emphasizes the importance of selecting resonator configurations based on specific application requirements Leveraging the advantages of near resonators enables the development of highly sensitive and accurate sensing systems , enhancing performance and expanding capabilities across various fields , including non - invasive blood glucose monitoring | ||
520 | _aهذا البحث يستكشف تصميم و أداء أجهزة استشعار لقياس مستوى السكر في الدم بدون إجراء اختبارات باستخدام موجات مايكروية مع نوعين مختلفين من المواد العازلة ذات ثابت عزل كهربائي مختلف بين نوعين (6,15 - Rogers 436002 (e و (3,38 - Rogers 4003 (e تم استخدام المحاكاة العددية لتحليل حساسية و فقدان الحساسية في أجهزة الاستشعار هذه أظهرت النتائج أن جهاز الاستشعار ذو ثابت العزل الأعلى (6.15 ) أظهر حساسية أكبر (11) ديسيبل لكل ملليغرام ديسيلتر) و فقدان أقل (0.55) مقارنة بجهاز الاستشعار ذو ثابت العزل الأقل(3.38 = e) ، و الذي أظهر حساسية 0.08 ديسيبل لكل ملليغرام / ديسيلتر و فقدان 0.68 هذه النتائج تشير إلى أن جهاز الاستشعار ذو ثابت العزل الأعلى (6.15 ) أكثر فعالية لمراقبة السكر المستمر بسبب حساسيته العالية و كفاءة الطاقة سيركز العمل المستقبلي على التحقق التجريبي من هذه النتائج و تحسين تصميم أجهزة الاستشعار بشكل أكبر لتعزيز أدائها في تطبيقات مراقبة مستوى السكر في الدم بدون إجراء اختبارات الدراسة الثانية في هذا البحث تستكشف تأثير قرب مركن الترددات على الحساسية في تصميم أجهزة الاستشعار باستخدام 436062 Rogers كمادة أساس ذات ثابت عزل كهربائي (ع) يبلغ 6.15 تقارن الدراسة حساسية المرينات القريبة و البعيدة باستخدام قياسات 521 لتقييم قدرتها على اكتشاف و قياس التغييرات في النظام تشير النتائج إلى أن المرينات القريبة ، و التي تقع على مسافة قريبة من مصدر الطاقة أو الهدف ، تظهر حساسية أعلى بسبب تحسن كفاءة تخزين و إرسال الطاقة في المقابل، تظهر المرينات البعيدة ، و التي تقع على مسافة أكبر ، حساسية منخفضة ، مما يجعل من الصعب اكتشاف التغييرات الطفيفة يؤكد هذا البحث على أهمية اختيار تكوينات المربنات على أساس متطلبات التطبيق المحدد الاستفادة من مزايا المرينات القريبة يمكن من تطوير أنظمة استشعار عالية الحساسية و دقيقة ، و تعزيز الأداء و توسيع القدرات في مجالات متنوعة ، بما في ذلك مراقبة مستوى السكر في الدم بدون إجراء اختبارات | ||
530 | _aIssued also as a digital file (for more information please check our Digital Repository) | ||
590 |
_aECCE _bECE |
||
700 | 1 |
_aAdel B. Abdel-Rahman _eSupervisor |
|
700 | 1 |
_aAsano Tanemasa _eco-Supervisor |
|
700 | 1 |
_aAhmed Allam _eco-Supervisor |
|
700 | 1 |
_aAdel B. Abdel-Rahman _eExaminator |
|
700 | 1 |
_aEhab Khalaf Ibrahim Hamad _eco-Examinator |
|
700 | 1 |
_aAhmed Ailam _eco-Examinator |
|
700 | 1 |
_aHany Ahmed Atallah Mohamed _eco-Examinator |
|
700 | 1 |
_aبدير , عادل , _eمشرف |
|
700 | 1 |
_aتناميسا , اسانو , _eمشرف مساعد |
|
700 | 1 |
_aعلام , احمد , _eمشرف مساعد |
|
700 | 1 |
_aبدير , عادل , _eمناقش |
|
700 | 1 |
_aحمد , ايهاب خلف ابراهيم , _eمناقش مساعد |
|
700 | 1 |
_aعلام , احمد , _eمناقش مساعد |
|
700 | 1 |
_aمحمد , هاني احمد عطالله , _eمناقش مساعد |
|
776 | 0 | 8 |
_iPrint version: _aChaffey, Dave, 1963- _tStrategy, implementation and practice _bEighth Edition. _dHoboken, NJ : Pearson, [2022] _z9781292400969 _w(DLC) 2021049493 |
901 | _aHaGeR | ||
902 | _aTH_001_03 | ||
942 |
_2lcc _n0 _cDISS |
||
999 |
_c6986 _d6986 |